Back To Search Results

Contact Lens–Related Complications

Editor: Kirandeep Kaur Updated: 6/11/2023 6:25:35 AM

Introduction

Contact lens (CL) use has increased tremendously owing to different indications and varied benefits.[1] The common indications of contact lenses are cosmetic, therapeutic, treatment of refractive error, and correction and control of myopia. There are approximately 140 million contact lens users globally, which is ever-increasing.[2] Many different types of contact lenses are available in the market to give every patient a spectacle-free life.[3]

Contact lenses act as a foreign body over the ocular surface and, despite their numerous benefits, are known to cause many complications.[4] With improvements in contact lens technology and continued research, the contact lens market has multiplied manifolds. Healthcare workers prescribing contact lenses must keep themselves updated regarding the benefits and problems associated with contact lenses. The complications can be broadly classified as infective and non-infective and conjunctival and corneal complications.[5]

The various corneal complications are epithelial edema, microcysts, abrasions, superficial punctate keratitis, contact lens-related peripheral ulceration, peripheral corneal staining, sterile corneal infiltrates, corneal neovascularization, microbial keratitis, bacterial keratitis, fungal keratitis, acanthamoeba keratitis, warpage, and endothelial changes.[6]

The conjunctival complications include allergic conjunctivitis, giant papillary conjunctivitis, and superior limbic keratoconjunctivitis. The other listed complications can be physical damage to the lens and discoloration. CL-related complications have decreased with CL materials, manufacturing techniques, and ocular hygiene advances. This activity focuses on various problems and complications associated with contact lenses and the necessary interventions to safeguard the patient from irreversible changes.[7]

Function

Register For Free And Read The Full Article
Get the answers you need instantly with the StatPearls Clinical Decision Support tool. StatPearls spent the last decade developing the largest and most updated Point-of Care resource ever developed. Earn CME/CE by searching and reading articles.
  • Dropdown arrow Search engine and full access to all medical articles
  • Dropdown arrow 10 free questions in your specialty
  • Dropdown arrow Free CME/CE Activities
  • Dropdown arrow Free daily question in your email
  • Dropdown arrow Save favorite articles to your dashboard
  • Dropdown arrow Emails offering discounts

Learn more about a Subscription to StatPearls Point-of-Care

Function

Tear and Contact Lens Interaction

The corneal tear film plays a vital role in maintaining the functional integrity of the cornea. It acts as a barrier, nourishes, and lubricates the corneal surface. The cornea is the primary refractive surface and comprises numerous refractive elements.[8]

It is vital to maintain the transparency and integrity of the cornea. The contact lens acts as a barrier between the tear film and the cornea and hampers the harmonious relationship between the two. This interaction reduces contact lenses' health, functioning, efficiency, efficacy, and acceptability.[9]

Lens Position and Tear Film Interaction

The lens can't be clamped or stuck to the cornea. The properties of the tear film, such as surface tension and viscosity, act as glue to hold the contact lens over the cornea surface.[10] Once the lens is inserted inside the eye, the conjunctival mucus rubs against the lens surface with several blinks, and tear fluid helps to wet the lens. The tear fluid spreads all over the lens surface, including the periphery, and helps to stick the lens to the surface.[11]

The pre-lens tear film acts as a plastic sheet to hold and tack the lens due to the firm, cohesive force between the water molecules and also serves as an adhesive force between water and the lens material. Approximately 11grams of force is needed to displace the lens as per experimental studies. When the tear film covering the lens breaks, the method of internal adhesion plays a key role. Negative pressure builds up between the lens, the corneal surface, and the tear film. It acts as a collar between the edge of the lens and the cornea, and this tear film acts as a container for the lens. When measured, this negative pressure is approximately 29 dynes/ cm.[12]

Optical Properties

The tear lens or the post-lens tear film interface plays an essential role in improving the function of the contact lens.[13] The irregularities on the corneal surface are filled by the back of the tear lens film, thus forming a uniform optical surface, and the front surface of the tear lens is shaped by the rear surface of the contact lens.[12]

The refractive index of the cornea is 1.376, and that of tears is 1.337. If the indices were equal, all degrees of the irregularities of the corneal surface, as well as astigmatism, would be perfectly corrected with the CL. With high degrees of astigmatism, residual astigmatism will be proportionately higher.[14]

Impact on Corneal Nourishment

Contact lens impacts the cornea in numerous ways.

  1. Retard the tear evaporation and interfere with tear hypertonicity.
  2. Acts as a barrier to the delivery of oxygen
  3. Traps the water and reduces waste disposal
  4. Injure or traumatize the dead epithelial cells.[15]

The hard CL covers approximately 50-80% of the corneal surface, and 70 to 85% of this area is permanently protected with normal lens mobility. The covered area is dependent on the nutrition of the tear film under the contact lens. The post-lens tear interface needs constant renewal to meet the corneal oxygen demands.[16]

It has been observed that under static conditions, the oxygen in the post-lens tear interface is exhausted within 90 seconds with hard or soft CL with 40% hydration. Further, the non-oxygen dependant pathway is significantly less efficient (approximately 1/18) than the oxygen-dependent pathway. There is an accumulation of lactic acid, the corneal nutrition is compromised, and this is corneal edema and haziness.[13]

The blinking mechanism creates a pump mechanism in the cornea-contact lens interface, and the pressure on the lid presses the contact lens, which expels the post-lens tear interface, which is then formed again. The pump efficacy depends upon

  • Tear volume behind the contact lens
  • Blink frequency
  • Percentage exchange of fluid with each blink[16]

The soft contact lens has a large diameter and comprehensively covers the lens surface. An aqualung effect is seen due to the hydrophilic nature of the lens. When blinking is absent, the corneal surface lacks oxygen, and the pump effect is missing. The oxygen delivery in soft lenses is only 10% of hard CL. But the lens flexibility helps create a capillary layer of fluid under the lens surface. The corneal deturgescence is reduced due to hypotonicity of the tear film resulting from excessive secretion of tears, change in blink rate, and impairment of evaporation.[17]

Lens Edge Effect

The contact lens is covered by the patient's tear film, resulting in a prism-shaped meniscus at the lens edge. If the edge of the lens comes in the pupillary area, it may result in the formation of the second focus of the image on the retina. This is common with low riding as well as high-riding lenses. This is called as ghost image effect or the edge flare effect.[18]

Lens Damage 

The lens spoilage can result from irregular contact lens interactions with the tear film. There can be multiple deposits on the contact lens surface which can affect the lens's optical properties. The deposits can damage the contact lens and reduce its working efficiency within six months. The lens deposits can be due to

  • Lens surface irregularities due to manufacturing defects
  • Tear film inadequacy
  • The porosity of the lens
  • Blink irregularity and deficiency
  • Immediate tear film break-up time
  • Altered tear film composition
  • Reduced tear film volume
  • Altered pH of the tear film[19]

Issues of Concern

Corneal Complications

Epithelial Complications

Epithelial Edema

Epithelial edema occurs secondary to hypoxia and is usually reversible. It is one of the commonest and earliest corneal complications.[15]

Microcysts

It occurs due to a decrease in corneal metabolism over a long period. They are seen most commonly with soft CL or extended wear contact lenses. These appear as small dots over the cornea of varying density and may mimic Cogan's microcystic dystrophy. These dots clear once the lens is removed. It is advised for these patients to switch from extended wear to daily wear or daily wear to gas-permeable lenses.[20]

Abrasions

These are caused by trauma or mechanical injury due to the lens or while insertion or removal of the lens. A foreign body embedded in the lens can also induce corneal abrasions.[21] The patients usually present with pain, redness, and watering, and the abrasions can be delineated on staining. The best treatment is contact lens removal and a course of topical antibiotics. Patching should be avoided in these cases due to fear of the eye getting infected. Once the infection resolves, contact lens wear can be initiated slowly.[22]

Superficial Punctate Keratitis

Superficial Punctate Keratitis (SPKs) occurs due to mechanical injury from the lens or during lens application.[23] Contact lens-induced chemical toxicity also results in SPK. This occurs secondary to preservatives present in the saline, not being able to clean the lens properly after using surfactant or enzyme cleansers, or failure to clean or neutralize hydrogen peroxide disinfectants.[24]

The associated ocular pathologies like dry eyes and blepharitis can also cause SPKs. Patients with SPK have to stop the lenses until the lesions resolve. The topical antibiotics, lubricating eye drops, and ointments also promote healing. The patient should be reassessed before deciding on CL wear again.[25]

Staining at 3 and 9 o Clock

This occurs due to corneal desiccation because of interruption of tear film or reduction of tear film at the nasal and temporal limbus. The main risk factors are poor lens edge tilt, limited lens movement, low riding lens, poor blink rate, presence of pinguecula, and adherence to the lens surface. It occurs most commonly in RGP lenses.[26]

Sterile Infiltrates

These are due to an inflammatory response to a particular antigen with associated corneal leucocyte infiltration from the adjacent limbal vessels.[27] The preservatives present in the contact lens cleaning solution are implicated as the major source of antigens. These appear as small opacities, which can be epithelial, subepithelial, or anterior stroma.[24] These infiltrate do not cause any symptoms and are detected on a routine examination. In some cases, a corneal infiltrate is an early indicator of microbial keratitis. The infiltrate disappears once the contact lens is discontinued. Once the infiltrate resolves, the patient can start wearing the CL with a preservative-free saline solution.[28]

Peripheral Corneal Ulceration

These ulcers are characterized by epithelial infiltration with an intact Bowman layer. The clinical presentation is different from that of microbial keratitis.[29] The peripheral corneal ulcers involve the paralimbal area and are white, crescentic to oval excavated ulcers and may be associated with thinning. There is mild congestion and focal infiltrates in contrast to microbial keratitis, which usually affects the visual axis and is characterized by epithelial defect and stromal melt. Peripheral corneal ulceration is also called marginal keratitis, and the primary causative agent is staphylococcal toxins.[30]

Corneal Neovascularization

This results from excessive hypoxia due to prolonged lens wear or a tight or thicker lens. Neovascularization can be superficial, deep, sectoral, or involve 360 degrees of the cornea.[4] In extended wear contact or therapeutic CL, a small amount of peripheral superficial vascularization is common (1 to 2 mm). A growth having a progression of more than 2 mm or involving a middle or deeper stroma is not common. Careful fitting of CL, regular follow-up of patients, and use of high oxygen transmission lenses with discontinuation of older ones is the treatment for neovascularization.[31]

Microbial (Infective) Keratitis

This is also known as contact lens-induced keratitis (CLIK). It is one of the serious complications but not a very common complication of contact lens wear. It may occur with any type of contact lens wear but is more common with soft CL and more familiar with extended wear CL.[4]

It starts with an epithelial defect secondary to trauma or hypoxic associated with microbial contamination. The significant risk factors are poor personal hygiene, inadequate lens cleaning, contamination of lens cover or lens cleaning solution, and the presence of dry eyes and blepharitis. The common organisms involved are Pseudomonas aeruginosa and Acanthamoeba. The other microorganisms, such as gram-negative and gram-positive bacteria, can also cause CL-induced keratitis.[4]

Acanthamoeba Castellani Infection

This condition is more common in patients using homemade saline for lenses, swimming in a swimming pool with CL, swimming in contaminated water, and exposure to tub and tap water. The most common clinical features are a pain out of proportion to clinical findings, irregularity of epithelium, and patchy stromal infiltrate.[32]

The late clinical features include stromal infiltrate, radial keratoneuritis, and elevated linear epithelial lines. Precautions must be taken to prevent this problem in patients. Prolonged lens wear, primarily sleeping with CL on, is a significant risk factor for acanthamoeba keratitis. Good ocular hygiene with regular cleaning and disinfection are the critical factors in preventing corneal ulcers in these patients. The patient should be explained in detail the risk factors and warning signs of corneal infection to avoid this ocular catastrophe. Once the corneal ulcer has occurred, it should be dealt with very early and meticulously.[33]

Pseudomonas Aeruginosa Keratitis

Pseudomonas is the most common cause of microbial keratitis in patients using CL. The patient usually presents with pain, redness, and discharge out of proportion and size of the infiltrate. The clinical findings are the presence of corneal infiltrate, ring infiltrates, and the presence of hypopyon in advanced cases.[34]

Fungal Keratitis 

Another sight-threatening complication associated with CL is fungal keratitis, characterized by dense gray-white stromal infiltrate, feathery margins, satellite lesions, endothelial exudate, and hypopyon. The diagnosis is by the corneal scraping of the infiltrate, and smearing and culture will pinpoint the microorganism.[35] The incidence of fungal keratitis secondary to CL wear varies from 10 to 21%. The most common causative agents are Aspergillus, Fusarium, and Candida. CL wear is the major cause of yeast-like fungal keratitis.[36]

Extended-wear lenses are associated with an increased risk of CL keratitis, followed by hydrogel and rigid gas-permeable contact lenses. Trauma with vegetative matter is the major cause, and topical antifungals are the mainstay of treatment. The commonly used antifungals are 5% Natamycin, 0.3% Amphotericin B, 1% voriconazole, 1% Itraconazole, and 1% Itraconazole. Non-resolving cases will require therapeutic keratoplasty.[4]

Warpage

Prolonged contact lens wear can induce severe and permanent astigmatism in the eyes in response to chronic hypoxia. The corneal shape changes temporarily due to prolonged use of impermeable hard CL. The warpage is usually detected on corneal topography and reverses with the discontinuation of CL. It can also cause a temporary reduction in visual acuity.[37]

The other complications with contact lenses can be foreign body tract formation, corneal Dellen, vacuoles, mucin ball formation, and dimple veiling.

Corneal Endothelial Changes

Contact lens wearers can have both short-term and long-term endothelial changes. The endothelial changes are thought to occur secondary to hypoxia which causes lactic acid accumulation in the cornea,  elevated levels of carbon dioxide, and reduced pH.[38]

Two types of changes are seen clinically

Endothelial bleb response

This is thought to occur minutes after using a thick, soft, or rigid contact lens. This is a transient effect and doesn't produce other side effects. The bleb changes usually resolve after 30 minutes of lens application or rapidly after lens discontinuation.[13]

Endothelial Polymegathism and Pleomorphism

These changes are noticed after a long time of contact lens wear. These changes are associated with corneal decompensation following intraocular surgery. These changes can be reduced by promoting the use of daily wear CL over extended-wear lenses and the use of RGP lenses over rigid PMMA lenses.[39]

Contact Lens-Related Discomfort

Per the Tear Film and Ocular Surface Society, discomfort associated with CL is characterized by occasional or regular adverse eye sensations associated with lens application, which may or may not be associated with visual discomfort, secondary to reduced harmony between the CL and surrounding ocular surface environment.[40]

This results in reduced usage or discontinuation of CL. The CL factors associated with discomfort are lens material, design, wearing time, hygiene, and fit to the ocular surface. The environmental factors are ocular surface changes, occupation, external temperature, humidity, associated medication use, and compliance. The goal of management is to reduce patient discomfort and modify the associated factors to provide a comfortable daily wear time.[4]

Conjunctival Complications

Allergic Conjunctivitis

This common complication has been reported with thiomersal-containing solutions. The patient presents with pain, redness, itching, and burning sensations. The reaction usually develops after days to months following exposure to thiomersal.[23] The examination reveals conjunctival hyperemia and the papillary response of the conjunctiva. Avoidance of thiomersal is the best treatment, and steroid eye drops should be used in tapering doses to prevent this reaction.[41]

Giant Papillary Conjunctivitis

This is an immunological complication in which the contact lens deposits and proteins act as an allergic stimulus.[23] The main risk factors for GPC include patient susceptibility, contact lens wear schedule, contact lens care regimen, lens material, and design. GPC is known to occur more commonly after soft CL. Patients with asthma, hay fever, and animal allergy are more susceptible.[4]

The most common symptoms are itching, redness, increased mucus production, photophobia, irritation, and reduction in lens tolerance. The upper palpebral conjunctiva show giant cobblestone papillae.[42] The GPC can be reduced by avoiding contact lens use, regular use of enzyme cleanser, change of lenses, avoiding heat disinfectants, and avoiding the use of CL with CL on. The lens should be avoided for at least 1 to 2 months, and treating the patients with sodium cromoglycate and steroid eye drops. Once the condition subsides, newer lenses may be fitted to avoid the recurrence.[43]

Superior Limbic Keratoconjunctivitis

Superior limbic keratoconjunctivitis is a hypersensitivity reaction to thiomersal or preservatives in contact lens solution. SLK is usually bilateral and asymmetric.[44]

The patients typically present with pain, redness, foreign body sensation, and contact lens intolerance. The anterior segment findings usually reveal inflammation and hypertrophy of superior bulbar conjunctiva that stain with Rose Bengal stain, punctate epithelial erosions, microphones of the superior cornea, and papillary hypertrophy of superior tarsal conjunctiva. The CL should be discontinued, and lubricating eyedrops should be used frequently. When the pathology resolves, the patient should be given a new pair of contact lenses and must be advised to use non-preserved saline and perform frequent lens cleaning.[44]

Clinical Significance

Contact lens-related problems and complications cause significant physical and mental trauma to the patient. It is a considerable economic burden for society. If not managed on time, these can result in a loss of visual acuity.[4] Every patient being prescribed contact lenses should be explained in detail the contact lens material properties, fitting technique, maintaining ocular hygiene, lens hygiene, and how to use and clean lenses to prevent the ill effects of the lens.[4]

The patients should receive explanations regarding the types of lenses available in the market and the pro and cons associated with each type of lens.[2] 

Other Issues

Complications Associated With Contact Lens

Contact lenses can be damaged or spoiled by use over time and may create various problems. There can be physical damage to the lens, change in lens color, loss of lens, and deposits over the lens.[45]

Physical Damage to the Lens

Damage to the lens can occur in the form of lens breakage, chipping, and cracking while inserting or removing the lens. The biochemical degradation of the lens also causes physical damage to the lens.[4]

Lens Discoloration

This can occur due to systemic uses of drugs such as rifampicin, fluorescein, and phenylephrine.[46]

Loss of Lens

This occurs more commonly in the pediatric age group than in adults. Most widely reported with rigid lenses than soft lenses and more familiar with extended wear lenses than daily wear.[47]

Deposits over Lens

This is another common problem with CL. This is more commonly reported with extended wear, daily-wear soft, RGP, and hard lenses. The deposits can be from the tear film, lens handling, cosmetics, topical drugs, and pollutants like dust and fumes.[20] The lens deposits occur secondary to a lack of personal hygiene, lens surface defects, age-related changes, material decay, and local ocular pathologies like blepharitis, meibomitis, lagophthalmos, and dry eyes.[25]

The lens deposits can be proteinaceous as well as lipid-laden deposits. These can cause physical damage to the lens, physiological impairment of diffusion of gases, blurred vision, hazy vision, halos, distortion, polyopia, photophobia, aberrations, and astigmatism. The treatment is that lenses should be replaced when the deposits are clinically significant. The daily-wear lenses should be replaced after every six months.[48]

Enhancing Healthcare Team Outcomes

Avoiding problems and complications with contact lenses is of prime importance for the patient and the treating surgeon. While prescribing CL to a patient, the treating surgeon must weigh the risk and benefits for a particular patient based on the primary indication.[49]

The patient undergoes refraction by an optometrist; the nursing and the allied staff help in patient recruitment, follow-up, and counseling, the treating surgeon, decides the type of contact lens; and the contact lens specialists and paramedical staff help in lens fit and counseling. Hence, this multidisciplinary approach help in patient management with a good outcome.[50]

Nursing, Allied Health, and Interprofessional Team Interventions

The nursing staff, allied health professionals, and the interprofessional team play a key role in deciding the type of contact lens, comfort with the contact lens, a preliminary diagnosis of any complications associated with the contact lens, and patient management with regular follow-up.[51]

Nursing, Allied Health, and Interprofessional Team Monitoring

The nursing staff, allied health professionals, and the interprofessional team play a key role in monitoring the patients who are regular contact lens wearers and determining any problems associated with the regular use of contact lenses.[52]

Media


(Click Image to Enlarge)
Digital image of the patient depicting central epithelial defect post overnight contact lens application
Digital image of the patient depicting central epithelial defect post overnight contact lens application
Contributed by Bharat Gurnani, MD

References


[1]

Falahati-Marvast F,Alipour F,Farokhzadian J,Ahmadian L, Determining the information needs of contact lens wearers for better education and more support: a qualitative study. BMC ophthalmology. 2021 Sep 7;     [PubMed PMID: 34493240]

Level 2 (mid-level) evidence

[2]

Pucker AD,Tichenor AA, A Review of Contact Lens Dropout. Clinical optometry. 2020;     [PubMed PMID: 32612404]


[3]

Grant T,Tang A, A Survey of Contact Lens Wearers and Eye Care Professionals on Satisfaction with a New Smart-Surface Silicone Hydrogel Daily Disposable Contact Lens. Clinical optometry. 2020;     [PubMed PMID: 32021532]

Level 3 (low-level) evidence

[4]

Alipour F,Khaheshi S,Soleimanzadeh M,Heidarzadeh S,Heydarzadeh S, Contact Lens-related Complications: A Review. Journal of ophthalmic     [PubMed PMID: 28540012]


[5]

Khan MH,Mubeen SM,Chaudhry TA,Khan SA, Contact lens use and its compliance for care among healthcare workers in Pakistan. Indian journal of ophthalmology. 2013 Jul;     [PubMed PMID: 23552347]

Level 2 (mid-level) evidence

[6]

Zimmerman AB,Nixon AD,Rueff EM, Contact lens associated microbial keratitis: practical considerations for the optometrist. Clinical optometry. 2016;     [PubMed PMID: 30214344]


[7]

Dupuis P, Prokopich CL, Hynes A, Kim H. A contemporary look at allergic conjunctivitis. Allergy, asthma, and clinical immunology : official journal of the Canadian Society of Allergy and Clinical Immunology. 2020:16():5. doi: 10.1186/s13223-020-0403-9. Epub 2020 Jan 21     [PubMed PMID: 31993069]


[8]

Zhang X,M VJ,Qu Y,He X,Ou S,Bu J,Jia C,Wang J,Wu H,Liu Z,Li W, Dry Eye Management: Targeting the Ocular Surface Microenvironment. International journal of molecular sciences. 2017 Jun 29;     [PubMed PMID: 28661456]


[9]

Mann A,Tighe B, Contact lens interactions with the tear film. Experimental eye research. 2013 Dec;     [PubMed PMID: 23886658]


[10]

Panaser A,Tighe BJ, Function of lipids − their fate in contact lens wear: an interpretive review. Contact lens     [PubMed PMID: 22317829]


[11]

Kumari A,Sharma PK,Garg VK,Garg G, Ocular inserts - Advancement in therapy of eye diseases. Journal of advanced pharmaceutical technology     [PubMed PMID: 22247860]


[12]

Marx S,Eckstein J,Sickenberger W, Objective Analysis of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection. Clinical optometry. 2020;     [PubMed PMID: 33244285]


[13]

Muntz A,Subbaraman LN,Sorbara L,Jones L, Tear exchange and contact lenses: a review. Journal of optometry. 2015 Jan-Mar;     [PubMed PMID: 25575892]


[14]

Mohammadi SF,Khorrami-Nejad M,Hamidirad M, Posterior corneal astigmatism: a review article. Clinical optometry. 2019;     [PubMed PMID: 31496856]


[15]

Bussan KA,Robertson DM, Contact lens wear and the diabetic corneal epithelium: A happy or disastrous marriage? Journal of diabetes and its complications. 2019 Jan;     [PubMed PMID: 30391097]


[16]

Guillon M,Dumbleton K,Theodoratos P,Patel K,Gupta R,Patel T, Pre-contact lens and pre-corneal tear film kinetics. Contact lens     [PubMed PMID: 30819629]


[17]

Gurnani B, Kaur K. Contact Lenses. StatPearls. 2024 Jan:():     [PubMed PMID: 35593861]


[18]

Siddireddy JS,Vijay AK,Tan J,Willcox M, The eyelids and tear film in contact lens discomfort. Contact lens     [PubMed PMID: 29054722]


[19]

Szczotka-Flynn LB,Pearlman E,Ghannoum M, Microbial contamination of contact lenses, lens care solutions, and their accessories: a literature review. Eye     [PubMed PMID: 20168237]


[20]

Binder PS, Complications associated with extended wear of soft contact lenses. Ophthalmology. 1979 Jun;     [PubMed PMID: 534093]


[21]

Lim CH,Turner A,Lim BX, Patching for corneal abrasion. The Cochrane database of systematic reviews. 2016 Jul 26;     [PubMed PMID: 27457359]

Level 1 (high-level) evidence

[22]

Salz JJ,Reader AL 3rd,Schwartz LJ,Van Le K, Treatment of corneal abrasions with soft contact lenses and topical diclofenac. Journal of refractive and corneal surgery. 1994 Nov-Dec;     [PubMed PMID: 7719534]

Level 3 (low-level) evidence

[23]

Urgacz A,Mrukwa E,Gawlik R, Adverse events in allergy sufferers wearing contact lenses. Postepy dermatologii i alergologii. 2015 Jun;     [PubMed PMID: 26161062]


[24]

Bradley CS,Sicks LA,Pucker AD, Common Ophthalmic Preservatives in Soft Contact Lens Care Products: Benefits, Complications, and a Comparison to Non-Preserved Solutions. Clinical optometry. 2021;     [PubMed PMID: 34522149]


[25]

Messmer EM, The pathophysiology, diagnosis, and treatment of dry eye disease. Deutsches Arzteblatt international. 2015 Jan 30;     [PubMed PMID: 25686388]


[26]

Findlay Q, Reid K. Dry eye disease: when to treat and when to refer. Australian prescriber. 2018 Oct:41(5):160-163. doi: 10.18773/austprescr.2018.048. Epub 2018 Oct 1     [PubMed PMID: 30410213]


[27]

Liu Q,Smith CW,Zhang W,Burns AR,Li Z, NK cells modulate the inflammatory response to corneal epithelial abrasion and thereby support wound healing. The American journal of pathology. 2012 Aug;     [PubMed PMID: 22728064]

Level 3 (low-level) evidence

[28]

Tabatabaei SA,Soleimani M,Johari M, Corneal ring infiltration in contact lens wearers. Oman journal of ophthalmology. 2017 May-Aug;     [PubMed PMID: 28757697]


[29]

Vemuganti GK,Murthy SI,Das S, Update on pathologic diagnosis of corneal infections and inflammations. Middle East African journal of ophthalmology. 2011 Oct;     [PubMed PMID: 22224015]


[30]

Garg P,Rao GN, Corneal ulcer: diagnosis and management. Community eye health. 1999;     [PubMed PMID: 17491983]


[31]

Lee DS,Kim MK,Wee WR, Biometric risk factors for corneal neovascularization associated with hydrogel soft contact lens wear in Korean myopic patients. Korean journal of ophthalmology : KJO. 2014 Aug;     [PubMed PMID: 25120337]

Level 2 (mid-level) evidence

[32]

Lindsay RG,Watters G,Johnson R,Ormonde SE,Snibson GR, Acanthamoeba keratitis and contact lens wear. Clinical     [PubMed PMID: 17697181]

Level 3 (low-level) evidence

[33]

Alfawaz A, Radial keratoneuritis as a presenting sign in acanthamoeba keratitis. Middle East African journal of ophthalmology. 2011 Jul;     [PubMed PMID: 21887085]


[34]

Wu YT,Zhu LS,Tam KP,Evans DJ,Fleiszig SM, Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear. Optometry and vision science : official publication of the American Academy of Optometry. 2015 Jun;     [PubMed PMID: 25955639]


[35]

Ansari Z,Miller D,Galor A, Current Thoughts in Fungal Keratitis: Diagnosis and Treatment. Current fungal infection reports. 2013 Sep 1;     [PubMed PMID: 24040467]


[36]

Acharya Y, Acharya B, Karki P. Fungal keratitis: study of increasing trend and common determinants. Nepal journal of epidemiology. 2017 Jun:7(2):685-693. doi: 10.3126/nje.v7i2.17975. Epub 2017 Jun 30     [PubMed PMID: 29181230]


[37]

Christy J,Gurnani B,Kaur K,Moutappa F, Contact lens warpage: Lost but found. Indian journal of ophthalmology. 2020 Aug;     [PubMed PMID: 32709811]


[38]

Leung BK,Bonanno JA,Radke CJ, Oxygen-deficient metabolism and corneal edema. Progress in retinal and eye research. 2011 Nov;     [PubMed PMID: 21820076]


[39]

Çavdarlı C,Topçu-Yılmaz P, Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters? Turkish journal of ophthalmology. 2018 Aug;     [PubMed PMID: 30202611]


[40]

Milner MS,Beckman KA,Luchs JI,Allen QB,Awdeh RM,Berdahl J,Boland TS,Buznego C,Gira JP,Goldberg DF,Goldman D,Goyal RK,Jackson MA,Katz J,Kim T,Majmudar PA,Malhotra RP,McDonald MB,Rajpal RK,Raviv T,Rowen S,Shamie N,Solomon JD,Stonecipher K,Tauber S,Trattler W,Walter KA,Waring GO 4th,Weinstock RJ,Wiley WF,Yeu E, Dysfunctional tear syndrome: dry eye disease and associated tear film disorders - new strategies for diagnosis and treatment. Current opinion in ophthalmology. 2017 Jan;     [PubMed PMID: 28099212]

Level 3 (low-level) evidence

[41]

Azari AA,Arabi A, Conjunctivitis: A Systematic Review. Journal of ophthalmic     [PubMed PMID: 32864068]

Level 1 (high-level) evidence

[42]

Villegas BV, Benitez-Del-Castillo JM. Current Knowledge in Allergic Conjunctivitis. Turkish journal of ophthalmology. 2021 Feb 25:51(1):45-54. doi: 10.4274/tjo.galenos.2020.11456. Epub     [PubMed PMID: 33631915]


[43]

Lievens CW,Cilimberg KC,Moore A, Contact lens care tips for patients: an optometrist's perspective. Clinical optometry. 2017;     [PubMed PMID: 30214367]

Level 3 (low-level) evidence

[44]

Sendele DD,Kenyon KR,Mobilia EF,Rosenthal P,Steinert R,Hanninen LA, Superior limbic keratoconjunctivitis in contact lens wearers. Ophthalmology. 1983 Jun;     [PubMed PMID: 6888855]


[45]

Alzahrani O,Alshehri FA,Alali AO,Alzahrani OH,Alzahrani ZA,AlZahrani A,Almazrou AA, Contact Lens Practices and Knowledge of Complications and its Association With Refractive Error in Saudi Arabia. Cureus. 2021 Jan 19;     [PubMed PMID: 33489642]


[46]

Silbert JA, A review of therapeutic agents and contact lens wear. Journal of the American Optometric Association. 1996 Mar;     [PubMed PMID: 8888826]


[47]

Bullimore MA, The Safety of Soft Contact Lenses in Children. Optometry and vision science : official publication of the American Academy of Optometry. 2017 Jun;     [PubMed PMID: 28514244]


[48]

Michaud L,Frenette B, Evaluation of Sodium Hyaluronate Lubricating Drops Used before Insertion of Contact Lenses on Symptomatology, Severity, and Intensity of Ocular Dryness. ISRN ophthalmology. 2012;     [PubMed PMID: 24575306]


[49]

Rankin A,Cadogan CA,Patterson SM,Kerse N,Cardwell CR,Bradley MC,Ryan C,Hughes C, Interventions to improve the appropriate use of polypharmacy for older people. The Cochrane database of systematic reviews. 2018 Sep 3;     [PubMed PMID: 30175841]

Level 1 (high-level) evidence

[50]

Shie AJ,Huang YF,Li GY,Lyu WY,Yang M,Dai YY,Su ZH,Wu YJ, Exploring the Relationship Between Hospital Service Quality, Patient Trust, and Loyalty From a Service Encounter Perspective in Elderly With Chronic Diseases. Frontiers in public health. 2022;     [PubMed PMID: 35692341]

Level 2 (mid-level) evidence

[51]

Konne NM,Collier SA,Spangler J,Cope JR, Healthy Contact Lens Behaviors Communicated by Eye Care Providers and Recalled by Patients - United States, 2018. MMWR. Morbidity and mortality weekly report. 2019 Aug 16;     [PubMed PMID: 31415490]


[52]

Busari JO,Moll FM,Duits AJ, Understanding the impact of interprofessional collaboration on the quality of care: a case report from a small-scale resource limited health care environment. Journal of multidisciplinary healthcare. 2017;     [PubMed PMID: 28652761]

Level 2 (mid-level) evidence