Synchronized Intermittent Mandatory Ventilation

Earn CME/CE in your profession:


Continuing Education Activity

Synchronized intermittent mandatory ventilation (SIMV) is a type of volume control mode of ventilation. With this mode, the ventilator will deliver a mandatory (set) number of breaths with a set volume while at the same time allowing spontaneous breaths. Spontaneous breaths are delivered when the airway pressure drops below the end-expiratory pressure ( trigger). This activity reviews SIMV, and highlights the role of the interprofessional healthcare team in evaluating, managing, and improving care for patients who are treated with SIMV.

Objectives:

  • Identify the indications and contraindications of synchronized intermittent mandatory ventilation.
  • Describe the equipment, personnel, preparation, and technique in regards to synchronized intermittent mandatory ventilation.
  • Review the potential complications and clinical significance of synchronized intermittent mandatory ventilation.
  • Outline interprofessional team strategies for improving care coordination and communication to advance synchronized intermittent mandatory ventilation and improve outcomes.

Introduction

Synchronized intermittent mandatory ventilation (SIMV) is a type of volume control mode of ventilation. With this mode, the ventilator will deliver a mandatory (set) number of breaths with a set volume while at the same time allowing spontaneous breaths. Spontaneous breaths are delivered when the airway pressure drops below the end-expiratory pressure (trigger). The ventilator attempts to synchronize the delivery of mandatory breaths with the spontaneous efforts of the patient. In contrast, to assist control ventilation (ACV), SIMV will deliver spontaneous volumes that are 100% driven by patient effort. Pressure support (PS) may be added to enhance the volumes of spontaneous breaths. SIMV was initially developed in the 1970s as a method to wean patients who are dependent on mechanical ventilation.[1] SIMV gained popularity and was the most widely used ventilatory mode for weaning, with 90.2% of hospitals preferring SIMV in a survey conducted in the 1980s.[2]

Anatomy and Physiology

Synchronized intermittent mandatory ventilation is a mode that comes installed on many ventilators. When SIMV was first invented, it required a "tee-piece" assembly modification to an existing ventilator. The "tee" is a corrugated tubing that connects to a heated nebulizer. One limb of the "tee" is open to the air and connected to a patient's port that has a one-way valve. The valve inserts into a hole drilled into the inspiratory limb, or "Y-piece," of the ventilator. This design allows the valve to close when the ventilator is on, delivering a preset tidal volume to the patient. When the patient takes a spontaneous breath, the valve opens and allows for inhalation of gas from the "tee-piece."[1] Newer generations of ventilators can support SIMV using a closed ventilator circuit with the assistance of the machine's microprocessor.[3]

Indications

Synchronized intermittent mandatory ventilation is typically used to help wean patients from the ventilator.[4] From a physiologic standpoint, SIMV has the advantage of avoiding acute respiratory alkalosis by allowing patients to achieve normal alveolar ventilation through an intact ventilatory drive.[5] One concern when using SIMV is that it can result in an increased work of breathing. One way to counteract this is by adding pressure support to the SIMV.[6] Mechanical ventilation, in general, is indicated in severe hypoxic and hypercapnic respiratory failure, often after a failed trial of non-invasive ventilation.[7]

Contraindications

Synchronized intermittent mandatory ventilation is a ventilator mode that enables partial mechanical assistance. This ventilator mode will provide a set number of breaths at a fixed tidal volume, but a patient can trigger a spontaneous breath with the volume determined by patient effort.[8] The maximal benefits of SIMV may only be realized by a patient who can take a spontaneous breath.

Equipment

Synchronized intermittent mandatory ventilation requires a ventilator that is programmable for the mode.

Personnel

Like any other mode of mechanical ventilation, SIMV requires trained respiratory therapists to monitor the ventilator and physician oversite.

Preparation

Preparation for ventilation with SIMV is similar to other modalities of mechanical ventilation. A patient must first have an advanced airway in place, and the patient must show improvement in their respiratory status with a plan to start the weaning process.

Technique or Treatment

Once the patient is ready to initiate the weaning process, it requires the appropriate settings on the ventilator. The parameters include tidal volume, respiratory rate, positive end-expiratory pressure (PEEP), the fraction of inspired oxygen (FiO2), and, if used, the pressure support setting. After the initiation of mechanical ventilation, it is best practice to obtain an arterial blood gas within 60 minutes and to titrate the ventilator settings accordingly.[9]

SIMV is rarely used for weaning. A survey of intensivists from various geographic regions showed SIMV was used 0 to 6% for weaning, depending on the region. More common methods of weaning are pressure support with PEEP (regional range of 56.5 to 72.3%) and T-piece (regional range of 8.9 to 59.5).[10]

Complications

Complications affecting patients undergoing mechanical ventilation include ventilator-associated pneumonia (VAP), barotrauma, acute respiratory distress syndrome (ARDS), pneumothorax, atelectasis, and post-extubation stridor. VAP is generally defined as a new persistent infiltrate on chest radiograph after a patient has been on mechanical ventilation for at least 48 hours, with at least three of the following associated symptoms: fever, leukopenia/leukocytosis, increased sputum production, rales, cough, or worsening gas exchange. ARDS is generally defined using the Berlin definition. The definition requires the measurement of the partial pressure of oxygen on a blood gas compared to the fraction of inspired oxygen the patient is currently receiving. There are three stages of ARDS: mild with a PaO2/FiO2 ratio less than or equal to 300 mm Hg, moderate with PaO2/FiO2 less than or equal to 200 mm Hg, and severe with PaO2/FiO2 less than or equal to 100 mm Hg.[11]

A study of pediatric patients in Egypt showed 39.9% of patients experienced complications, which equates to 29.5 complications per 1000 ventilation days. The complications were broken down into VAPs (27.3% or 20.19/1000 ventilator days), pneumothorax (10.6% or 7.82/1000 ventilator days), atelectasis (4.4% or 3.28/1000 ventilator days), and post-extubation stridor (2.4% or 1.76/1000 ventilator days).[12]

Asynchrony is another complication, defined as a mismatch between the patient's demand and the ventilator supply of measures such as ventilation rate, flow, volume, or pressure.[13] Studies of neonatal patients show that a neurally adjusted ventilatory assist has significant fewer asynchrony events that SIMV.[14] In adult patients with acute respiratory distress syndrome, there was no significant difference in ventilator asynchrony amongst patients in assist/control mode and SIMV. Additionally, there was no difference in the duration of mechanical ventilation or hospital length of stay.[15]

Clinical Significance

If the patient does not trigger a breath, only the scheduled mandatory breaths will be delivered. Perceived benefits of SIMV include improved patient comfort on the ventilator, reduced work of breathing, reduction in ventilator dyssynchrony, and ease of ventilator weaning. Clinical trials evaluating some of these benefits have not overwhelmingly supported these benefits. SIMV, and specifically SIMV-PS, continues to be a commonly used ventilator mode in the many US intensive care units and especially in surgical ICUs. One of the newer modes of mechanical ventilation, airway pressure release ventilation (APRV), is a variant of SIMV-PS. In APRV, the inspiratory time is longer than the expiratory time, providing an inverse I to E ratio to improve oxygenation.[3]

SIMV was a popular method of mechanical ventilation when it was initially invented. Newer studies demonstrate that it may not be the most effective mode of ventilation. A study of preterm infants shows that SIMV has significantly worse mean airway pressure, duration of time from the onset of weaning to extubation, duration of nasal continuous positive airway pressure support after extubation, and an extubation failure rate when compared to pressure support ventilation with volume guarantee.[16] In adult patients receiving coronary artery bypass grafting, adaptive support ventilation showed statistically lower amounts of atelectasis, number of changes in mechanical ventilator settings, number of ventilator alarms, and hospital length of stay when compared to SIMV.[17] After placing a patient on mechanical ventilation, many intensivists begin to plan their strategy to wean and ultimately liberate the patient from mechanical ventilation. Studies have shown that SIMV is the least efficient technique of weaning when compared to pressure support ventilation and intermittent T-piece trials.[18] Patients with acute respiratory distress syndrome also have shown increased ventilator weaning duration time with SIMV.[19] Similarly, in patients who underwent orthotopic liver transplantation, pressure support SIMV had a significantly higher number of modifications to ventilator settings and duration of mechanical ventilation than patients in adaptive support ventilation.[20]

Enhancing Healthcare Team Outcomes

The management of patients receiving SIMV requires interprofessional teamwork amongst clinicians, pulmonologists, nurses, respiratory therapists, and other allied health professions. Respiratory therapists generally are trained to closely monitor the ventilator and be able to troubleshoot when problems occur. The nursing staff has direct bedside monitoring of the ventilated patient, usually in an intensive care unit or similar facility. In neonatal patients, SIMV has been associated with a higher risk of bronchopulmonary dysplasia and increased with duration of ventilation when compared to high-frequency oscillatory ventilation. With all types of ventilation, only one individual should be assigned to change the parameters. Anytime a parameter is changed, they should chart the change and notify the nurse. Daily morning rounds should be undertaken with the team members to ensure that everyone is aware of the treatment plan. Nurses who play a crucial role in managing patients on ventilators should always monitor the patient for adverse events and complications associated with ventilation. [Level I] Communication between members of the interprofessional healthcare team should be immediate to ensure that outcomes are not compromised.[21] [Level V]

Nursing, Allied Health, and Interprofessional Team Interventions

Nursing interventions for SIMV are similar to interventions required for all patients who are receiving mechanical ventilation. Evidence-based interventions for ventilator patients include the ABCDEF bundle. This bundle stands for assess, prevent, and manage pain; to have a daily spontaneous awakening and breathing trials; choice of analgesia and sedation; to assess, prevent, and manage deliriumearly mobility and exercise; and family engagement.[22] Implementing this bundle has led to proven substantial reductions in the number of days on mechanical ventilation, hospital length of stay, and total overall intensive care unit and hospital cost.[23]

Nursing, Allied Health, and Interprofessional Team Monitoring

Nursing and respiratory therapists must closely monitor any patient on mechanical ventilation, including those on SIMV. Ventilator asynchrony and dyssynchrony result when the patient and ventilator are out of sync and should be minimized. There are seven types of events: ineffective effort, double trigger, premature cycling, delayed cycling, reverse triggering, flow starvation, and auto-cycling. Graphical displays on ventilators can help nurses, and respiratory therapists identify ventilator asynchrony. These graphics include pressure and flow waveforms. Further education may be required to identify these events on waveforms monitoring, but prompt identification will increase the amount of time a patient spends in synchrony with their ventilator.[24]


Details

Editor:

Kim Bird

Updated:

7/3/2023 11:48:29 PM

References


[1]

Downs JB, Klein EF Jr, Desautels D, Modell JH, Kirby RR. Intermittent mandatory ventilation: a new approach to weaning patients from mechanical ventilators. Chest. 1973 Sep:64(3):331-5     [PubMed PMID: 4518325]


[2]

Venus B, Smith RA, Mathru M. National survey of methods and criteria used for weaning from mechanical ventilation. Critical care medicine. 1987 May:15(5):530-3     [PubMed PMID: 3568717]

Level 3 (low-level) evidence

[3]

MacIntyre N. Design Features of Modern Mechanical Ventilators. Clinics in chest medicine. 2016 Dec:37(4):607-613. doi: 10.1016/j.ccm.2016.07.002. Epub     [PubMed PMID: 27842742]


[4]

Ghodrati M, Pournajafian A, Khatibi A, Niakan M, Hemadi MH, Zamani MM. Comparing the Effect of Adaptive Support Ventilation (ASV) and Synchronized Intermittent Mandatory Ventilation (SIMV) on Respiratory Parameters in Neurosurgical ICU Patients. Anesthesiology and pain medicine. 2016 Dec:6(6):e40368. doi: 10.5812/aapm.40368. Epub 2016 Oct 2     [PubMed PMID: 28975076]


[5]

Hudson LD, Hurlow RS, Craig KC, Pierson DJ. Does intermittent mandatory ventilation correct respiratory alkalosis in patients receiving assisted mechanical ventilation? The American review of respiratory disease. 1985 Nov:132(5):1071-4     [PubMed PMID: 3933391]


[6]

Patel DS, Rafferty GF, Lee S, Hannam S, Greenough A. Work of breathing during SIMV with and without pressure support. Archives of disease in childhood. 2009 Jun:94(6):434-6. doi: 10.1136/adc.2008.152926. Epub 2009 Feb 17     [PubMed PMID: 19224888]


[7]

Kreppein U, Litterst P, Westhoff M. [Hypercapnic respiratory failure. Pathophysiology, indications for mechanical ventilation and management]. Medizinische Klinik, Intensivmedizin und Notfallmedizin. 2016 Apr:111(3):196-201. doi: 10.1007/s00063-016-0143-2. Epub 2016 Feb 22     [PubMed PMID: 26902369]


[8]

Luo XY, Hu YH, Cao XY, Kang Y, Liu LP, Wang SH, Yu RG, Yu XY, Zhang X, Li BS, Ma ZX, Weng YB, Zhang H, Chen DC, Chen W, Chen WJ, Chen XM, Du B, Duan ML, Hu J, Huang YF, Jia GJ, Li LH, Liang YM, Qin BY, Wang XD, Xiong J, Yan LM, Yang ZP, Dong CM, Wang DX, Zhan QY, Fu SL, Zhao L, Huang QB, Xie YG, Huang XB, Zhang GB, Xu WB, Xu Y, Liu YL, Zhao HL, Sun RQ, Sun M, Cheng QH, Qu X, Yang XF, Xu M, Shi ZH, Chen H, He X, Yang YL, Chen GQ, Sun XM, Zhou JX, Acute Brain Injury and Critical Care Research Collaboration (ABC Research Collaboration). Lung-protective Ventilation in Patients with Brain Injury: A Multicenter Cross-sectional Study and Questionnaire Survey in China. Chinese medical journal. 2016 Jul 20:129(14):1643-51. doi: 10.4103/0366-6999.185869. Epub     [PubMed PMID: 27411450]

Level 2 (mid-level) evidence

[9]

McConnell RA, Kerlin MP, Schweickert WD, Ahmad F, Patel MS, Fuchs BD. Using a Post-Intubation Checklist and Time Out to Expedite Mechanical Ventilation Monitoring: Observational Study of a Quality Improvement Intervention. Respiratory care. 2016 Jul:61(7):902-12. doi: 10.4187/respcare.04191. Epub 2016 Mar 1     [PubMed PMID: 26932381]

Level 2 (mid-level) evidence

[10]

Burns KEA, Raptis S, Nisenbaum R, Rizvi L, Jones A, Bakshi J, Tan W, Meret A, Cook DJ, Lellouche F, Epstein SK, Gattas D, Kapadia FN, Villar J, Brochard L, Lessard MR, Meade MO. International Practice Variation in Weaning Critically Ill Adults from Invasive Mechanical Ventilation. Annals of the American Thoracic Society. 2018 Apr:15(4):494-502. doi: 10.1513/AnnalsATS.201705-410OC. Epub     [PubMed PMID: 29509509]


[11]

ARDS Definition Task Force, Ranieri VM, Rubenfeld GD, Thompson BT, Ferguson ND, Caldwell E, Fan E, Camporota L, Slutsky AS. Acute respiratory distress syndrome: the Berlin Definition. JAMA. 2012 Jun 20:307(23):2526-33. doi: 10.1001/jama.2012.5669. Epub     [PubMed PMID: 22797452]


[12]

Meligy BS, Kamal S, El Sherbini SA. Mechanical ventilation practice in Egyptian pediatric intensive care units. Electronic physician. 2017 May:9(5):4370-4377. doi: 10.19082/4370. Epub 2017 May 25     [PubMed PMID: 28713509]


[13]

Holanda MA, Vasconcelos RDS, Ferreira JC, Pinheiro BV. Patient-ventilator asynchrony. Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia. 2018 Jul-Aug:44(4):321-333. doi: 10.1590/S1806-37562017000000185. Epub 2018 Jul 6     [PubMed PMID: 30020347]


[14]

Mally PV, Beck J, Sinderby C, Caprio M, Bailey SM. Neural Breathing Pattern and Patient-Ventilator Interaction During Neurally Adjusted Ventilatory Assist and Conventional Ventilation in Newborns. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2018 Jan:19(1):48-55. doi: 10.1097/PCC.0000000000001385. Epub     [PubMed PMID: 29189671]


[15]

Luo J, Wang MY, Liang BM, Yu H, Jiang FM, Wang T, Shi CL, Li PJ, Liu D, Wu XL, Liang ZA. Initial synchronized intermittent mandatory ventilation versus assist/control ventilation in treatment of moderate acute respiratory distress syndrome: a prospective randomized controlled trial. Journal of thoracic disease. 2015 Dec:7(12):2262-73. doi: 10.3978/j.issn.2072-1439.2015.12.63. Epub     [PubMed PMID: 26793348]

Level 1 (high-level) evidence

[16]

Liu WQ, Xu Y, Han AM, Meng LJ, Wang J. [A comparative study of two ventilation modes in the weaning phase of preterm infants with respiratory distress syndrome]. Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics. 2018 Sep:20(9):729-733     [PubMed PMID: 30210024]

Level 2 (mid-level) evidence

[17]

Moradian ST, Saeid Y, Ebadi A, Hemmat A, Ghiasi MS. Adaptive Support Ventilation Reduces the Incidence of Atelectasis in Patients Undergoing Coronary Artery Bypass Grafting: A Randomized Clinical Trial. Anesthesiology and pain medicine. 2017 Jun:7(3):e44619. doi: 10.5812/aapm.44619. Epub 2017 Apr 22     [PubMed PMID: 28856111]

Level 1 (high-level) evidence

[18]

Esteban A, Frutos F, Tobin MJ, Alía I, Solsona JF, Valverdú I, Fernández R, de la Cal MA, Benito S, Tomás R. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. The New England journal of medicine. 1995 Feb 9:332(6):345-50     [PubMed PMID: 7823995]


[19]

Tanaka R. [Strategy of mechanical ventilation for acute respiratory distress syndrome]. Masui. The Japanese journal of anesthesiology. 2013 May:62(5):532-40     [PubMed PMID: 23772526]


[20]

Celli P, Privato E, Ianni S, Babetto C, D'Arena C, Guglielmo N, Maldarelli F, Paglialunga G, Rossi M, Berloco PB, Ruberto F, Pugliese F. Adaptive support ventilation versus synchronized intermittent mandatory ventilation with pressure support in weaning patients after orthotopic liver transplantation. Transplantation proceedings. 2014 Sep:46(7):2272-8. doi: 10.1016/j.transproceed.2014.06.046. Epub 2014 Aug 20     [PubMed PMID: 25150607]


[21]

Greenough A, Murthy V, Milner AD, Rossor TE, Sundaresan A. Synchronized mechanical ventilation for respiratory support in newborn infants. The Cochrane database of systematic reviews. 2016 Aug 19:(8):CD000456. doi: 10.1002/14651858.CD000456.pub4. Epub 2016 Aug 19     [PubMed PMID: 27539719]

Level 1 (high-level) evidence

[22]

Moraes FDS, Marengo LL, Silva MT, Bergamaschi CC, Lopes LC, Moura MDG, Fiol FSD, Barberato-Filho S. ABCDE and ABCDEF care bundles: A systematic review protocol of the implementation process in intensive care units. Medicine. 2019 Mar:98(11):e14792. doi: 10.1097/MD.0000000000014792. Epub     [PubMed PMID: 30882653]

Level 1 (high-level) evidence

[23]

Hsieh SJ, Otusanya O, Gershengorn HB, Hope AA, Dayton C, Levi D, Garcia M, Prince D, Mills M, Fein D, Colman S, Gong MN. Staged Implementation of Awakening and Breathing, Coordination, Delirium Monitoring and Management, and Early Mobilization Bundle Improves Patient Outcomes and Reduces Hospital Costs. Critical care medicine. 2019 Jul:47(7):885-893. doi: 10.1097/CCM.0000000000003765. Epub     [PubMed PMID: 30985390]


[24]

Bulleri E, Fusi C, Bambi S, Pisani L. Patient-ventilator asynchronies: types, outcomes and nursing detection skills. Acta bio-medica : Atenei Parmensis. 2018 Dec 7:89(7-S):6-18. doi: 10.23750/abm.v89i7-S.7737. Epub 2018 Dec 7     [PubMed PMID: 30539927]